The T340 steam hose is a wire-braided EPDM family published at 270 psi (18 bar) for saturated steam from -40 °F to +410 °F (-40 °C to +210 °C). Braid count rises with bore: one at 1/2 in, two at 3/4 in and larger.
This page explains what the T340 name actually includes, what its published limits rule out, and how to write a specification that a second supplier can quote against. Every figure below is the maker’s own published value.
About a 15-minute read at 250 words per minute; metric and imperial values are given side by side.
What the T340 Steam Hose Designation Actually Covers
The T340 label is not one hose. It is a catalog designation that ties five properties into a single name. Those properties are 270 psi maximum working pressure, a saturated steam temperature window, a heat-resistant EPDM tube, a steel wire braid, and a pin-pricked EPDM cover. The range is made by Alfagomma and cataloged in North America by Kuriyama.
Two variants sit inside the designation. T340AH carries the red heat-resistant EPDM cover. T340AA is the companion variant in the same family. Both are published at 270 psi (18 bar) maximum working pressure, so the pressure figure is a family-wide number rather than a per-item number.
The bore, the cut length, and the end connections stay open until a buyer writes them down. A purchase order that says only “T340” is therefore incomplete. Table 1 sets out the published figures that define the designation, and the table is best read as one fixed set of properties.
Table 1. Published figures that define the T340 designation.
| Property | Published figure | Note |
|---|---|---|
| Maximum working pressure | 270 psi (18 bar) | Saturated steam service |
| Constant service temperature | -40 °F to +410 °F (-40 °C to +210 °C) | Continuous saturated steam duty |
| Intermittent temperature | to +450 °F (+232 °C) | Short excursions only |
| Tube | Black extruded heat-resistant EPDM | Conductive; carries static charge toward ground |
| التعزيز | High-tensile steel wire braid | One braid at 1/2 in; two at 3/4 in and larger |
| الغلاف | Red EPDM (AH), pin-pricked | Wrapped fabric-impression finish |
| Cover marking | ALFAGOMMA – ITALY 340 18 BAR (270 PSI) STEAM – DRAIN AFTER USE | Printed along the cover, read left to right |
Read that string field by field: maker and country, family code, pressure pair, service, then the drain rule.
Specifications quoted for the named product are those the manufacturer publishes; confirm them against the maker’s current datasheet before you order.
HENGHUA is not affiliated with, and does not distribute, the named brand.
Read that table as one fixed set of properties rather than a menu. A change of bore moves the braid count, and the cover finish is functional rather than cosmetic. An EPDM braided steam hose is defined by the whole set of attributes, not by a single number.

Figure 1. Coiled red cover with pin-pricking, wire braid visible where the end is cut back.
T340 Steam Hose Pressure and Temperature Ratings in Plain Numbers
The published pair is 270 psi (18 bar) against saturated steam from -40 °F to +410 °F, which is -40 °C to +210 °C. Intermittent excursions to +450 °F (+232 °C) are allowed. The word intermittent does real work in that sentence, because it separates a short excursion from a continuous duty.
The same 18 bar ceiling appears in the ISO 6134 definition of a Type 2 high-pressure steam hose. Converted, 18 bar is 261 psi (calculated), so the published 270 psi is the maker’s own expression of that standard ceiling. A hose at this ceiling should be read as sitting at the limit rather than comfortably below it.
The numbers have to travel as a pair. With a steam hose, 270 psi and 410 °F belong to the same published row, and quoting one without the other hides the duty. That pairing is what a specification line has to capture.
Table 2. Rating pairs for the range, with converted values marked as calculated.
| Rating | Metric | Imperial | Where it applies |
|---|---|---|---|
| Maximum working pressure | 18 bar | 270 psi | Continuous saturated steam |
| Constant service, low end | -40 °C | -40 °F | Cold ambient start-up |
| Constant service, high end | +210 °C | +410 °F | Continuous saturated steam |
| Intermittent, high end | +232 °C | +450 °F | Short steam excursions |
| ISO 6134 Type 2 ceiling | 18 bar | 261 psi (calculated) | Standard definition of high-pressure steam hose |
| ISO 6134 Type 1 ceiling | 6 bar | 87 psi (calculated) | Standard definition of low-pressure steam hose |
A lower-pressure ISO 6134 Type 1 hose covers 6 bar and 164 °C, so the type number alone tells a buyer which pressure class is being discussed. For the difference between the rating a hose carries and the pressure at which it fails, the site’s guide to working pressure versus burst pressure is a useful companion.
How the Braid Count Changes Across the T340 Steam Hose Range
The published reinforcement rule is short. A 1/2 in bore uses one high-tensile steel wire braid. Bores of 3/4 in and above use two. The pressure rating stays the same while the reinforcement steps up with diameter.
Braid carries the hoop load that internal pressure creates. A larger bore on the same wall thickness sees more total force, so the maker adds a second braid rather than lowering the rating. This EPDM braided steam hose therefore keeps one family pressure figure while the build changes underneath it.
A specification that names only the pressure misses that point. Braid count is the part of the build that follows bore size, and it is the part a supplier can get wrong when copying a short description. Table 3 gives the published 1/2 in dimensions and the braid rule for the larger sizes.
Table 3. Braid rule and published 1/2 in dimensions.
| Item | 1/2 in bore | What to require for other bores |
|---|---|---|
| Steel wire braid layers | 1 | Require two braids at 3/4 in and larger |
| Inside diameter | 13 mm | Supplier’s published ID for that bore |
| Outside diameter | 0.91 in (23 mm) | Supplier’s published OD for that bore |
| Minimum bend radius at 68 °F | 5 in | State the radius at your bore |
| Standard length | 50 ft | State cut length and length tolerance |
| الوزن | 0.28 lb/ft | Ask for weight per foot |
The metric and imperial figures describe one bore in two ways, so 13 mm and 0.91 in are not two different hoses. The site’s millimeter-to-inch conversion chart covers the arithmetic for the rest of a size list.

Figure 2. Cutaway: black tube, one braid layer at the small bore, two layers at the larger bore.
Why a Steam Hose at 270 PSI Needs a Pin-Pricked EPDM Cover
Steam passes slowly through an EPDM wall. If that vapor is trapped under a sealed cover, the cover blisters and lifts away from the braid. Pin-pricking gives the vapor a path out, and every T340 steam hose cover carries it together with a wrapped fabric-impression finish.
On the AH variant the cover is red heat-resistant EPDM. The color is a recognition aid rather than a performance claim, but it makes a mixed hose rack easier to read at a glance. The conductive tube is the other safety feature, because it bleeds static charge from the steam path toward the grounded end fitting.
Table 4 breaks the build into layers and gives the recognition clue for each one. The table is written as a checklist on purpose, because each layer can be confirmed on a hose in the rack without cutting it open.
Table 4. Layer, material, function, and recognition clue for the T340 build.
| طبقة | Material in this build | الوظيفة | How to recognize it |
|---|---|---|---|
| Tube | Black extruded heat-resistant EPDM, conductive | Carries the steam and bleeds static charge to the grounded fitting | Smooth black bore, no fabric impression |
| التعزيز | High-tensile steel wire braid | Resists the hoop stress that internal pressure creates | Layer count rises with bore |
| الغلاف | Red EPDM (AH), pin-pricked | Protects the braid and vents vapor that reaches the wall | Fine perforations and a wrapped fabric texture |
| Marking | Printed ink on the cover | Records pressure, steam service, and the drain instruction | Text including DRAIN AFTER USE |
The material reasoning behind an EPDM tube in saturated steam duty sits in the site’s existing note on EPDM steam hose and saturated steam, which is the right page for the compound science.

Figure 3. Left, perforated cover venting vapor through the pin holes; right, sealed cover lifting in blisters.
Where the T340 Steam Hose Range Is Published For Use
The maker publishes the range for high-pressure equipment cleaning in refineries, processing plants, and shipyards, using saturated steam up to 270 psi and 410 °F. A second published use is thawing and de-icing outdoor lines during cold seasons.
Those jobs share a pattern. Each one needs a short, tough hose that can be dragged to a nozzle or a lance, then coiled and drained at the end of the shift. None of them involves a detergent washdown, which is exactly where the published limits draw a line.
Shipyard work adds salt spray, ozone, and abrasion against deck edges to the duty. A pin-pricked cover helps with internal vapor, but it does not protect against external wear, so a hose in that service needs routing care and regular inspection.
Table 5. Published uses and the hose features each one depends on.
| Published use | Steam condition | Features it depends on |
|---|---|---|
| High-pressure equipment cleaning in refineries and processing plants | Saturated steam to 270 psi and 410 °F | Steel wire braid, pin-pricked cover, conductive tube |
| Shipyard cleaning and deck work | Saturated steam to 270 psi and 410 °F | Cover abrasion resistance, bend radius, low weight per foot |
| Thawing and de-icing of outdoor lines | Saturated steam to 270 psi and 410 °F | Cold-weather flexibility, standard 50 ft length |
Published Limits on the T340 Steam Hose
The maker publishes three limits, and each one rules out a use that a buyer might otherwise assume is included. They are worth reading before the pressure rating, not after it.
The range is not for steam cleaner use. A 270 psi steam hose in this family serves a plant steam line or a lance, not the whip that sits behind a pressure-washer boiler. Use with superheated steam will shorten hose life, so the intermittent temperature figure is not a license for continuous superheated duty.
The range is also not recommended for washdown applications where detergent or oils are present. Detergent attacks the cover from outside while oil attacks the tube from inside. Finally, the hose must be drained after every use, because residual condensate blisters the tube in a failure the trade calls popcorning.
Two assembly limits sit alongside those three. A coupling attached with clamps or bands can pull the assembly rating below the hose rating. Universal quick-acting couplings must not be used on steam hose at all, whatever pressure they carry.
None of these limits is a defect. They describe where a braided EPDM steam hose belongs, and they are the reason a specification should name the duty as well as the pressure. The guide for steam hose use, testing, and inspection published as ARPM IP-11-1 covers the maintenance side of the same story.
How to Specify an Equivalent Hose Against the Same Numbers
An equivalent hose is easy to specify once the designation stops being mistaken for a specification. Write each published line onto your own datasheet as a requirement, then ask every supplier to state its own published value against that line. The braid count that an EPDM braided steam hose needs at each bore belongs in that list too.
Start with the pressure and the temperature window, then the tube compound and its electrical behavior. Add the reinforcement rule by bore, the cover finish and its pin-pricking, the standard length, and the marking text. A supplier that cannot quote the drain instruction on the cover is not offering the same article.
Table 6 turns those lines into a worksheet that can be sent out with a request for quotation. Each row leaves room for the supplier’s own published figure, so the comparison stays factual.
Table 6. Specification worksheet for an equivalent steam hose.
| Specification line | Published value in this range | What to require on your own datasheet |
|---|---|---|
| Pressure rating | 270 psi (18 bar) | State maximum working pressure and any design factor separately |
| Temperature window | -40 °F to +410 °F constant; +450 °F intermittent | Split constant duty from intermittent duty |
| Tube | Black extruded heat-resistant EPDM, conductive | Name the compound family and the electrical behavior |
| التعزيز | Braid count set by bore, per Table 3 | Tie braid count to bore, not to pressure alone |
| الغلاف | Red pin-pricked EPDM, wrapped fabric finish | Require pin-pricking and state the cover color |
| الطول | 50 ft standard for the 1/2 in size | State the cut length and the length tolerance |
| Marking | Pressure, steam service, drain instruction | Require the drain instruction on the cover |
The site’s steam hose category shows the bore range and pressure splits HENGHUA builds to, including the perforated covers that steam duty requires. Two product pages cover a 170 °C saturated line and a 230 °C high-temperature line. The same worksheet applies to a second maker’s compact range, at this planned URL — publish before linking compact steam-service build.
Handling, Drain-Down and Storage for Steam Hose 270 PSI Class
A steam hose that is drained after every use lasts far longer than one coiled warm and left wet. Condensate sits against the tube, permeates it, and starts the blistering that ends the hose early. The drain instruction printed on the cover is the cheapest maintenance step in the whole installation.
Bend radius matters on a stiff braided hose. The published minimum for the 1/2 in size is 5 in at 68 °F, so a tight cold-weather coil is a genuine risk. Support the weight so it does not hang on the couplings, and keep the hose clear of sharp edges and hot surfaces.

Figure 4. Hose run on support brackets with a wide coil, couplings left free of the floor.
Store the hose coiled, drained, and out of direct sunlight. Ozone and ultraviolet light age rubber covers, and a cover that has hardened no longer protects the braid underneath it.
Inspection belongs on the same routine. A cover that has blistered, a braid that has rusted through the cover, or a coupling that has moved on the shank all point to a hose that should leave service.
Matching Couplings and Assemblies to a 270 PSI Steam Hose
On a steam hose, 270 psi is the hose figure alone. Once couplings are crimped or clamped on, the assembly carries its own rating, and that rating can be lower than the hose’s. Grounding is the second assembly issue.
The conductive tube only grounds static charge if the end fitting is bonded to it and the assembly is earthed. A coupling that breaks that path leaves the charge with nowhere to go. Universal quick-acting couplings should not be used on steam hose, whatever rating they carry.
Test evidence belongs in the file. A hydrostatic test follows ISO 1402 and an impulse test follows ISO 6803, and both are routine bench work for a hose plant. Assembly guidance published by NAHAD notes that clamp- or band-attached couplings can reduce the assembly working pressure below the hose rating.
Abrasion testing follows ISO 4649 when cover wear is the concern, and BS 5342 is the British national steam hose standard that appears alongside ISO 6134 in maker literature. For background on who builds hoses to this duty split, the site’s about page describes the plant, the lines, and the quality systems behind it.
T340 Steam Hose FAQs
What does the T340 steam hose designation actually cover?
The T340 steam hose designation covers a family of wire-braided EPDM hoses rather than a single item. It fixes the 270 psi maximum working pressure, the saturated steam window from -40 °F to +410 °F, the conductive black EPDM tube, the steel wire braid, and the red pin-pricked cover. Bore, length, and end connections stay open for the buyer to specify.
Which bores use one steel wire braid, and which use two?
The published rule is by bore size. A 1/2 in bore uses one high-tensile steel wire braid. Sizes of 3/4 in and above use two braids. The family keeps its single 270 psi rating across both, because the second braid carries the extra hoop load that a larger diameter creates at the same internal pressure.
What pressure and temperature pair does the range publish?
It publishes 270 psi (18 bar) for saturated steam service from -40 °F to +410 °F, which is -40 °C to +210 °C. Intermittent excursions to +450 °F (+232 °C) are allowed. The 18 bar ceiling matches the ISO 6134 Type 2 definition of a high-pressure steam hose, so the rating sits at the standard limit rather than below it.
Why does a 270 psi steam hose need a pin-pricked cover?
Steam permeates slowly through an EPDM wall, and a sealed cover traps that vapor against the braid. The trapped vapor blisters and lifts the cover, so the hose carries pin-pricking to give it a release path. The wrapped fabric-impression finish and the red color of the AH cover are the visible clues outside.
Can the T340 hose be used with a steam cleaner?
No. The maker publishes a clear limit that the range is not for steam cleaner use. A hose in this family serves a fixed plant steam line or a lance, while a steam cleaner uses its own high-temperature whip behind a boiler. Choosing the wrong one puts a line hose into a duty its cover and tube were not built for.
What happens if superheated steam is used continuously?
Superheated steam places a higher thermal load on rubber than saturated steam does at the same pressure. The published note says that use with superheated steam will shorten hose life. The +450 °F (+232 °C) figure is an intermittent allowance, so continuous superheated duty calls for a hose built for that service instead.
Why must the hose be drained after every use?
Residual condensate sits against the tube after shutdown and permeates it from the inside. The tube then blisters away from the reinforcement, a failure the trade calls popcorning. That is why the cover carries a DRAIN AFTER USE instruction, and why draining the hose after every shift is the cheapest thing an operator can do.
What is the minimum bend radius at 1/2 in?
The published minimum bend radius for the 1/2 in bore is 5 in at 68 °F. That figure applies at room temperature and does not improve when the hose is cold, so a tight coil in winter is a real risk. Support the hose so its weight does not hang on the couplings.
How do I specify an equivalent hose against the same numbers?
Write each published line as a requirement on your own datasheet: pressure, temperature window, tube compound and electrical behavior, braid count by bore, cover finish and pin-pricking, length, and the marking text. Then ask every supplier to state its own published value against each line. A hose that matches all of them is equivalent for the same duty.
Can universal quick-acting couplings be used on steam hose?
No. Universal quick-acting couplings must not be used on steam hose. They are not built for the pressure and temperature pair, and a steam release at the joint is a serious hazard. Use couplings rated for the duty, and remember that clamp- or band-attached fittings can lower the assembly pressure below the hose rating.
Deciding Whether the T340 Steam Hose Range Fits Your Duty
Decide the duty first, then the hose. If the job is plant steam at or below 270 psi and 410 °F, with saturated steam and a short lance or cleaning line, a braided EPDM family like this one fits the work. If the job is a steam cleaner, a washdown with detergent or oils, or continuous superheated steam, it does not.
Then write the specification line by line, require pin-pricking and the drain instruction on the cover, and confirm every figure against the maker’s current datasheet before the first order. احصل على عرض أسعار وعينات مجانية to compare a HENGHUA steam hose against the same published numbers.
About HENGHUA
HENGHUA manufactures hoses and fittings for distributors, retailers, and OEM brands worldwide. The steam line is built with an EPDM or CR tube, one to two layers of steel wire braid or four to six layers of wire spiral, and a pin-pricked cover. Bores run from 3/8 in to 4 in. Saturated steam service reaches 210 °C and superheated steam service reaches 230 °C, and a separate food-grade hose series covers food and beverage duties.
The factory covers a 35,000 m² site with 95 production lines and exports to more than 70 countries. Quality systems follow ISO 9001, IATF 16949, and ISO 14001, and an in-house laboratory runs hydrostatic tests to ISO 1402 and impulse tests to ISO 6803. Commercial terms include factory-direct pricing, short lead times for volume orders, and a warranty, with OEM and ODM support, custom cut lengths at ±1% tolerance, and cover printing or private label.





