A saturated steam chart is a lookup table that links the pressure of steam to its saturation temperature, specific volume and density. For a hose engineer it is the first reference to open, because saturated steam cannot have its pressure and temperature chosen independently. This guide reproduces a standard chart, then shows how to read every column for steam hose selection.

The saturated steam chart below is indexed by gauge pressure, the number a plant gauge actually shows. Absolute pressure, saturation temperature in both scales, specific volume, density and enthalpy fill the remaining columns. Every property value on this page is copied cell by cell from one reference table, so the figures here stay consistent with the standard steam data the industry already uses. The source is the IAPWS-IF97 formulation for water and steam properties.

About a 14-minute read at 250 words per minute; how to read a chart column by column and turn it into a hose specification.

What a Saturated Steam Chart Shows

A saturated steam chart describes steam that sits in equilibrium with liquid water. At any given pressure, saturated steam exists at exactly one temperature, and that pairing is fixed by thermodynamics rather than chosen by an operator. The chart therefore has one independent variable, pressure, and every other property follows from it.

One independent variable is what separates saturated steam from superheated steam. Superheated steam has been heated above its saturation temperature at the same pressure, so its pressure and temperature become two independent variables. A saturated steam chart covers only the first case, which is the case most plant steam systems actually run. The material side of the same decision is covered in the guide to EPDM steam hose for saturated steam.

The chart is a snapshot of one physical situation. It assumes the steam is dry, that is, free of entrained water droplets, and that it has given up no heat to the surroundings. In a real plant the steam leaves the boiler slightly wet and cools a little along the run, so the table is a reference point rather than a measurement. What it fixes is the ceiling: the hottest the steam can be at that pressure while it stays saturated.

Sketch of the saturated steam curve, showing temperature rising with pressure along the saturation line

Figure 1. The saturation line links one value of pressure to one value of temperature, with no second choice available.

Saturated Steam Chart: Pressure and Temperature Pairs

The table is indexed by gauge pressure because that is the reading a plant gauge gives. Absolute pressure is gauge pressure plus the local atmospheric pressure, taken here as a fixed offset. For hose selection the temperature column usually decides the material, because heat aging tracks temperature rather than pressure. Table 1 gives the saturation temperature in Celsius and Fahrenheit, so a US process sheet needs no temperature conversion.

Table 1. Saturated steam property chart: pressure, temperature, specific volume, density and enthalpy.

Gauge pressure (bar g)Absolute pressure (bar a)Saturation temperature (C)Saturation temperature (F)Specific volume (m3/kg)Density (kg/m3)Enthalpy (kJ/kg)
01.01100.0211.91.67370.5972675.5
12.01120.4248.70.88041.1362706.5
23.01133.7272.60.60331.6572725.1
34.01143.7290.70.46102.1692738.2
45.01151.9305.50.37392.6752748.2
56.01158.9318.10.31493.1752756.2
67.01165.0329.00.27233.6732762.8
78.01170.5338.90.24004.1672768.4
89.01175.4347.80.21464.6602773.1
910.01179.9355.90.19415.1522777.2
1011.01184.1363.40.17725.6422780.7
1213.01191.7377.00.15106.6212786.5
1415.01198.3389.00.13167.5992791.0
1617.01204.4399.80.11668.5782794.5
1819.01209.8409.70.10469.5582797.3
2021.01214.9418.80.094910.5402799.4
2223.01219.6427.30.086811.5262800.9
2526.01226.1438.90.076913.0112802.5

Read the table by entering at the pressure column and then moving right. At 0 bar g the saturation temperature is 100.0 degrees Celsius, at 6 bar g it is 165.0, and at 18 bar g it reaches 209.8. Those three steps alone explain why a low-pressure steam line and a high-pressure line need different hose construction even when both carry steam. The hose range built for this service is listed on the EPDM steam hose 170 degrees Celsius page.

The figures also align with the hose standard. ISO 6134 Type 1 covers a maximum working pressure of 0.6 MPa, which is 6 bar, at 164 degrees Celsius. Type 2 covers 1.8 MPa, which is 18 bar, at 210 degrees Celsius. The chart sits within one degree Celsius of both, because the standard rounds its own values.

Note where the table skips a step. It lists every bar up to ten, then continues in steps of two through twenty-two and finishes at twenty-five, because those are the values a steam system is often designed around. A pressure between two rows is found by interpolation, and the result is accurate enough for a hose decision. The reinforcement choice changes at the class boundaries rather than between neighboring rows.

Reading Specific Volume and Density from the Saturated Steam Chart

Specific volume and density are the two columns that describe how much space steam occupies. Specific volume is the volume filled by one kilogram of dry saturated steam, and density is its reciprocal. As pressure rises, steam becomes denser and the specific volume falls, so a high-pressure line moves the same mass through a smaller bore.

The specific volume and the density columns move in opposite directions. At 0 bar g the specific volume is 1.6737 and the density is 0.597. At 10 bar g the specific volume has fallen to 0.1772 while the density has climbed to 5.642. That drop is not linear, so the value should always be read from the chart rather than estimated.

Two numbers describe the same steam from opposite sides. A large specific volume means the steam is thin and occupies a lot of room, while a small specific volume means it is packed into a dense state. For a hose the practical consequence is the bore. If a line is sized for a thin, low-pressure steam and then run at a higher pressure, the same bore passes far more mass than it was chosen for.

Sketch of specific volume falling as pressure rises for saturated steam

Figure 2. Specific volume falls as pressure rises, so the same mass of steam fills less space at higher pressure.

The density change matters for flow and for hose sizing. Denser steam carries more mass at the same velocity, and velocity drives erosion of the tube wall. When a line is extended or a nozzle is changed, the flow calculation should be repeated against the density read from the chart at the true working pressure.

Steam Pressure, Steam Temperature and Hose Limits

Steam pressure and steam temperature are not free choices on a saturated line. Fix one and the other is fixed with it, so a specification that quotes only one of them is incomplete. The temperature at that pressure is what sets the hose material limit, the cover compound and the end fitting.

The steam pressure also sets the reinforcement. A saturated line at 6 bar g runs at 165.0 degrees Celsius, which sits at the boundary of a low-pressure steam hose. Push to 18 bar g and the steam temperature reaches 209.8, where a steel wire reinforced construction becomes the normal choice.

A saturated line is also the reason a steam hose is not read the same way as a water hose. For a water line the two ratings are independent, so each is checked on its own. For steam the pair moves along one curve, so a single gauge reading fixes both the load and the material limit at once. That coupling is what makes the table so useful at the specification stage.

Table 2. Gauge pressure, saturation temperature and the hose class or next step each row points to.

Gauge pressure (bar g)Saturation temperature (C)Hose classPenguatan
6165.0Low pressureTextile
10184.1High pressureSteel wire
18209.8High pressureSteel wire
20214.9Above Type 2 (choose by the hose temperature rating)Steel wire
25226.1Above Type 2 (choose by the hose temperature rating and confirm the end fitting)Steel wire

The pressure rating and the temperature rating move together, so the two are often checked on one page, as in the notes on steam hose temperature rating versus pressure rating. A buyer who reads only one of them can still order the wrong hose.

Saturated Steam Table vs Superheated Steam

A saturated steam table stops at the saturation line, and that boundary is what makes it useful. Above the line the steam is superheated, so its temperature and pressure are independent of each other, and the table’s pairing stops applying. The practical test is simple: if the measured temperature is higher than the chart lists for that pressure, the steam is superheated.

Superheated steam is used where the steam must stay dry through a long distribution run, or where a process needs extra heat. For hose selection, superheated steam is harder on the tube, because the wall sees a true temperature that the saturation curve cannot predict. A saturated steam table gives the reference point, then the true temperature is measured or supplied by the process.

The boundary between the two cases is not always obvious on a live line. Steam that starts superheated can cool back to saturation after heat loss, and steam that starts saturated can pick up heat from a hot surface. For a hose decision the safe route is to specify for the higher of the two wall values, so the tube is never the weakest element in the circuit.

Table 3. Saturated steam and superheated steam compared for hose selection.

PointSaturated steamSuperheated steam
StateIn equilibrium with liquid waterHeated above the saturation line
Pressure and temperatureLocked togetherIndependent of each other
Chart appliesYes, on the saturation lineNo, a separate reference is needed
Effect on the tubeWall temperature known from pressureWall temperature must be measured

Superheated steam and saturated steam are checked in different ways. For saturated steam the reading path is pressure to saturation temperature to hose limit. For superheated steam and for hot water, pressure and temperature are independent, so the allowance has to follow a true temperature correction instead. The notes on hose pressure at elevated temperature set out that separate path.

Water and steam phase regions diagram showing liquid, saturated steam and superheated steam zones

Figure 3. The phase regions of water: liquid below the saturation line, saturated steam on it, and superheated steam above it.

How to Use Each Column for Hose Selection

A chart is only useful when each column maps to a decision. Read the columns in a fixed order, starting with pressure and finishing with density, so that a strong reading on one column does not hide a weak reading on another. The table below pairs every column with the hose question it answers.

The order matters because the columns are not equally decisive. Pressure and temperature rule out a construction outright, while volume and density refine a choice that is already safe. Checking the hard limits first avoids the trap of matching a hose to a flow figure and then finding that the wall runs far above the compound limit. Work from the limits inward.

Table 4. What each chart column answers when a hose is selected.

ColumnQuestion it answersHose action
Gauge pressureHow much pressure the line holdsSelect the pressure class
Saturation temperatureHow hot the wall will runSelect the tube and cover compound
Specific volumeHow much space the steam fillsCheck the bore and the velocity
DensityHow much mass fills a unit volumeConfirm the flow against the bore
EnthalpyHow much heat the steam carriesSize the heat load with it; the hose class follows from pressure and temperature

A worked example keeps the logic visible. Suppose a cleaning line runs at 10 bar g. The chart gives a saturation temperature of 184.1 degrees Celsius, a specific volume of 0.1772 and a density of 5.642. That temperature is above the 164 degree ceiling of a Type 1 hose, so the line needs a high-pressure construction.

Two supporting links help here. The working pressure versus burst pressure guide sets out the first principle in detail. The hydraulic hose pressure rating notes apply the same logic to a different service. Both are useful when a steam line shares a plant with other hose services.

Common Mistakes When Reading the Chart

Three mistakes account for most misread charts. The first is mixing gauge and absolute pressure, which shifts the temperature and can push a selection over a limit. The second is reading the row above or below by accident on a long table. The third is assuming the chart still applies after the steam has been superheated.

The gauge and absolute mix-up is the most damaging, because a line quoted at 18 bar a is not the same as 18 bar g. The chart lists both, so the fix is to confirm which unit the plant uses and then stay in that column. A second check is to confirm the steam is saturated at the point of use, not at the boiler, because pressure drop along the run lowers the saturation temperature.

A final habit is to note the source of the table you are reading. Curated reference values agree closely with one another, but a table copied from an unknown source may carry a transcription error. Compare a few familiar rows, such as the boiling point of water at atmospheric pressure, against a second reference before you trust the rest.

Table 5. Common chart reading errors and how to avoid them.

MistakeWhat it causesHow to avoid it
Gauge read as absoluteTemperature taken at the wrong pressureConfirm the unit before entering the table
Wrong row readA selection that is one step outTrace across with a straight edge
Chart applied to superheated steamThe wall temperature is understatedMeasure the true temperature
Chart read at the boilerThe value is taken at the wrong pointRead the pressure at the point of use

A vendor table calls for the same care as a property table. Reading a supplier chart is a different exercise from reading a physical property table. The Parker steam hose chart is a useful example of a manufacturer layout, with its own columns and its own service notes.

Saturated Steam Chart FAQs

What is a saturated steam chart used for?

It is a working reference for anyone who sizes steam equipment. One row links a single pressure to its saturation temperature, its specific volume and its density, so the wall condition and the flow condition can be read off together. A hose engineer uses that single row to fix the material limit before the bore and the flow are checked. That is why it is the first table to open before a steam hose is specified.

Why is the chart indexed by gauge pressure?

Plant gauges report gauge pressure, not absolute pressure, so the table is built to match the instrument an operator actually reads. Absolute pressure is then listed beside it as a convenience column. Keeping the gauge column first removes a conversion step from every lookup, and it also avoids the error of entering the table with an absolute value and reading the wrong row.

How do I read the saturation temperature from the chart?

Enter the table at the gauge pressure column and move across to the temperature column. That value is the saturation temperature for the steam at that pressure. Because the relationship is fixed, there is no need to measure the temperature separately once the pressure is known. Always confirm that the pressure you entered is gauge pressure and not absolute pressure.

What is the difference between saturated and superheated steam?

Saturated steam is in equilibrium with liquid water, so it has one temperature for each pressure. Superheated steam sits above the saturation line, so pressure and temperature can be chosen independently. The saturation line is the boundary between them. A property chart stops at that line, and anything above it needs a separate reference and a separate limit check.

Does higher steam pressure always mean a higher steam temperature?

On a saturated line, yes. The two values are locked together, so raising the pressure raises the temperature with it, and the chart shows that pairing directly. The rule breaks down only when the steam is superheated or when hot water is involved, because in those two cases the values can move independently.

Can the chart be used for hot water lines?

The chart is a background reference for hot water lines rather than a limit. Hot water below its boiling point is a single-phase liquid, so its temperature is set by the process rather than by the pressure alone. The saturation line shows the point at which that water would begin to boil at a given pressure. For an actual hot water hose limit, use the temperature rating of the hose instead.

Is a saturated steam table the same as a steam hose rating chart?

No. The property table describes the physical properties of steam itself, while a hose rating chart describes what a hose can carry. The property table tells you the temperature at a pressure. The hose chart tells you the pressure and temperature the product is approved for. Read them together, but never treat one as a substitute for the other.

What is the density column for?

The density column states how much mass of steam fills one cubic meter at that pressure. It is the reciprocal of the specific volume column, so the two always agree. Density matters when the flow through a line has to be recalculated, because it fixes how much mass passes a given bore at a given velocity.

Sourcing Steam Hose Against a Saturated Steam Chart

The saturated steam chart turns a process condition into a hose specification, but only when every value is read at the real working pressure. Confirm the gauge pressure, read the temperature from the chart, and match the reinforcement and material to that row. A maintenance planner, a distributor quoting a batch and an OEM specifying a new skid all read the same row; what changes is the pressure they enter it with. A hose chosen this way carries the correct margin into service.

Get a quote and free samples

About HENGHUA

HENGHUA is a professional manufacturer of hose and fittings, supplying distributors, retailers and OEM brands around the world. The steam hose line is built around an EPDM tube with a textile or steel wire reinforcement, and the cover is pin-pricked for steam duty. The range includes an EPDM steam hose rated to 170 degrees Celsius and an EPDM high-temperature steam hose rated to 230 degrees Celsius. End terminations can be supplied as clamp-type safety fittings, flanges or threads.

Assemblies are built in the factory to the required length, with branded printing, private label and OEM or ODM options available. Terms are factory-direct, with short bulk lead times and a warranty on the finished assembly. Send the working pressure, the operating temperature and the bore, and we will quote against them.