{"id":7055,"date":"2026-11-17T08:21:36","date_gmt":"2026-11-17T08:21:36","guid":{"rendered":"https:\/\/www.henghuahose.com\/?p=7055"},"modified":"2026-11-17T08:21:38","modified_gmt":"2026-11-17T08:21:38","slug":"composite-hose-size-chart","status":"publish","type":"post","link":"https:\/\/www.henghuahose.com\/ko\/composite-hose-size-chart\/","title":{"rendered":"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop"},"content":{"rendered":"<p>A hose size chart is a decision tool, not a conversion table. The bore decides flow, the flow decides loading time, and the loading time decides whether the size was right; the <a href=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-flow-rate\/\" target=\"_blank\" rel=\"noopener\">flow sizing guide<\/a> turns that chain into a number. Inches and millimeters are only the first two columns.<\/p>\n\n\n\n<p>This guide gives the size chart for common composite hose bores, explains what else changes with diameter, and shows how to move from a required flow to a size without guessing.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg\" alt=\"Two composite hose ends of different bore side by side on a bench, cut faces toward the camera\" class=\"wp-image-7038\" srcset=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg 800w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero-300x225.jpg 300w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero-768x576.jpg 768w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero-16x12.jpg 16w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>Figure 1. Two bores, cut square and stood side by side. The wall, the helix and the liner all read at the cut face, which is the first column of any size chart.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-use-a-hose-size-chart\">Why Use a Hose Size Chart?<\/h2>\n\n\n\n<p>A chart earns its place because three numbers move together as the bore increases, and buyers usually track only one.<\/p>\n\n\n\n<p>Flow rises roughly with the square of the diameter. Pressure drop falls as the bore rises. And weight, bend radius and cost rise with it. A chart puts those movements side by side, which is what a sizing decision needs.<\/p>\n\n\n\n<p>The alternative is to specify by the connection size, and that works only when the pump and the vessel already dictate the bore. On a new line, or one that is being upgraded, the chart does the work.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-inches-map-to-millimeters\">How Do Inches Map to Millimeters?<\/h2>\n\n\n\n<p>The first two columns are nominal bore in inches and millimeters. Composite hose is usually designated in inches on site and in millimeters on drawings, so both belong on the chart.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Nominal size<\/th><th>Bore<\/th><th>Minimum bend radius<\/th><th>Typical weight<\/th><\/tr><\/thead><tbody><tr><td>1 inch<\/td><td>25 mm<\/td><td>Tight, hose handled easily<\/td><td>Light<\/td><\/tr><tr><td>1.5 inch<\/td><td>38 mm<\/td><td>Moderate<\/td><td>Light to moderate<\/td><\/tr><tr><td>2 inch<\/td><td>50 mm<\/td><td>Moderate<\/td><td>Moderate<\/td><\/tr><tr><td>3 inch<\/td><td>80 mm<\/td><td>300 mm at Type 3<\/td><td>Heavy when filled<\/td><\/tr><tr><td>4 inch<\/td><td>100 mm<\/td><td>375 mm at Type 3<\/td><td>Needs two people<\/td><\/tr><tr><td>6 inch<\/td><td>150 mm<\/td><td>550 mm at Type 3<\/td><td>Cradle or crane<\/td><\/tr><tr><td>8 inch<\/td><td>200 mm<\/td><td>750 mm at Type 3<\/td><td>Mechanical handling<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Table 1. Composite hose size chart with the bend radius and weight character that go with each bore. Confirm the values against the type table for the build ordered.<\/em><\/p>\n\n\n\n<p>Two cautions apply to the first column, and the <a href=\"https:\/\/www.henghuahose.com\/ko\/convert-mm-to-inches-formula-chart-instant-calculator\/\" target=\"_blank\" rel=\"noopener\">mm to inch converter<\/a> handles the arithmetic while the chart handles the decision. First, a nominal size is not a measured bore, and the tolerance matters when a hose has to enter a clamp or a fitting. Second, an imperial nominal size does not always correspond exactly to the metric figure quoted in a drawing.<\/p>\n\n\n\n<p>Measure the bore before ordering a replacement, because a chart describes nominal sizes and a used hose may not be one. Two minutes with a tape measure is cheaper than a return, and more accurate than a part number read from an old drawing. A hose that has been used for years may be a nominal size that no longer matches the marking, particularly where fittings have been changed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-else-changes-with-the-bore\">What Else Changes With the Bore?<\/h2>\n\n\n\n<p>Four properties move with diameter, and each affects a different part of the installation.<\/p>\n\n\n\n<p>Bend radius rises, so the route needs more space at the same pressure, as the <a href=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-bend-radius\/\" target=\"_blank\" rel=\"noopener\">bend radius table<\/a> shows by type. Weight rises faster than the diameter suggests, because the wall and helix both grow. Cost rises with material, so the price per meter is not a linear function of size. And the fitting becomes the limiting component, because a camlock at 6 inch is rated lower than the same style at 2 inch.<\/p>\n\n\n\n<p>That last point catches buyers who size on the hose rating. A nominal size is only half the assembly; the other half is the connection, and the lower of the two governs.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils.jpg\" alt=\"Three coils of blue composite hose of different bore standing side by side in a workshop\" class=\"wp-image-7039\" srcset=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils.jpg 800w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils-300x225.jpg 300w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils-768x576.jpg 768w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils-16x12.jpg 16w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-coils-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>Figure 2. Three bores in coil. The diameter difference is obvious at a glance; the flow difference behind it is not, which is why the chart exists.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-you-read-flow-from-the-chart\">How Do You Read Flow From the Chart?<\/h2>\n\n\n\n<p>Flow is read as a band, not a figure. Each bore has a range where velocity is sensible for a liquid transfer, and outside that range the line is either noisy and erosive or slow and uneconomic.<\/p>\n\n\n\n<p>A hose bore chart is easiest to use when the sequence is fixed. A practical sequence runs in four steps. Start with the volume to be moved and the time available. Convert that to a flow. Read the bore band that carries it at a sensible velocity. Then check the pressure drop at that bore against what the pump can deliver.<\/p>\n\n\n\n<p>If the drop is too high, the bore goes up, and if the bore cannot go up, the time available has to change instead. That conversation is easier with a chart than with an argument. If the bore that fits the flow cannot fit the route, the route or the time has to change, and that is a project decision rather than a hose decision.<\/p>\n\n\n\n<p>A hose bore chart is most useful at this point, because it shows where the two constraints cross. The figure that comes out is a starting point for the sizing calculation, not a substitute for it.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Flow band<\/th><th>Bore that suits it<\/th><th>\ucc38\uace0<\/th><\/tr><\/thead><tbody><tr><td>Low, under 10 m\u00b3\/h<\/td><td>1 to 1.5 inch<\/td><td>Fine for dosing and small transfer<\/td><\/tr><tr><td>Moderate, 10 to 30 m\u00b3\/h<\/td><td>2 inch<\/td><td>The common industrial default<\/td><\/tr><tr><td>High, 30 to 80 m\u00b3\/h<\/td><td>3 to 4 inch<\/td><td>Tanker and terminal work<\/td><\/tr><tr><td>Very high, above 80 m\u00b3\/h<\/td><td>6 to 8 inch<\/td><td>Needs mechanical handling<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Table 2. Flow bands against bore. Bands are indicative and assume a low-viscosity liquid at ambient temperature.<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"where-does-pressure-drop-come-in\">Where Does Pressure Drop Come In?<\/h2>\n\n\n\n<p>Pressure drop per meter rises with flow and falls sharply as the bore increases. That relationship is why a small increase in diameter often solves a loading-time problem that a bigger pump does not.<\/p>\n\n\n\n<p>Two factors are specific to hose. The wall is not perfectly smooth, so the friction factor is higher than for drawn pipe. And the hose bends, and a bend adds a local loss that a straight-length calculation ignores.<\/p>\n\n\n\n<p>A pressure drop per meter figure is a property of the bore and the flow, and it doubles as a quick check on any proposal. For a short transfer with few bends, the straight-length figure is close enough. For a long run with several bends, the bend losses dominate, and a calculation that ignores them will understate the drop.<\/p>\n\n\n\n<p>Where the product is viscous, temperature matters as much as bore, because viscosity falls as product warms. A line sized on cold viscosity is often larger than the duty needs.<\/p>\n\n\n\n<p>A worked habit helps more than a formula. Take the flow, convert it to a velocity at each candidate bore, and check the velocity against what the product tolerates. Aromatic solvents and light oils tolerate higher velocities than viscous products, and slurries tolerate less than either. The velocity limit is the one figure that comes from the product rather than from the hose.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-about-tolerances\">What About Tolerances?<\/h2>\n\n\n\n<p>Bore tolerance is the column nobody asks about and everybody suffers from.<\/p>\n\n\n\n<p>A hose at the top of its tolerance may not fit a clamp or a fitting designed at nominal. A hose at the bottom may pass product more slowly than the calculation assumed, though the effect is small compared with a size error.<\/p>\n\n\n\n<p>For critical work, ask for the measured bore rather than the nominal one, and record it. That single number prevents the fit problem that appears at installation rather than at purchase. It also settles the occasional dispute about whether a delivered hose matches the order, which is cheaper to resolve with a measurement than with a return.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-you-choose-a-composite-hose-size\">How Do You Choose a Composite Hose Size?<\/h2>\n\n\n\n<p>Five inputs decide a hose size chart entry: flow, allowable pressure drop, product viscosity, route and connection. The hose bore chart narrows the choice; the connection often fixes it.<\/p>\n\n\n\n<p>Start with flow and drop, which set the band. Then check viscosity, which can move the band up. Then the route, which sets the maximum bend radius the bore can accept. Then the connection, which may cap the size regardless.<\/p>\n\n\n\n<p>If the connection is smaller than the bore, the assembly is limited by the connection and the extra hose diameter buys nothing. That is why a hose size chart should be read next to a <a href=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-end-fitting-material\/\" target=\"_blank\" rel=\"noopener\">fitting table<\/a> rather than on its own.<\/p>\n\n\n\n<p>Where the line is handled, add handling to the list, because a bore that needs a cradle is a bore that slows every connection. A bore that needs a crane is a bore that gets used less carefully than one that two people can move, and the second is usually faster over a shift.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-changes-at-the-ends-of-the-chart\">What Changes at the Ends of the Chart?<\/h2>\n\n\n\n<p>The smallest and largest sizes each bring a constraint that the middle of the chart does not.<\/p>\n\n\n\n<p>At 1 inch and below, the fitting dominates. A small hose is stiff relative to its bore, the wall is thin, and the fitting is a large share of the assembly cost. Pressure drop is also high, so small sizes suit short runs and dosing rather than transfer.<\/p>\n\n\n\n<p>At 6 inch and above, handling dominates. The hose needs a cradle, the assembly needs two people or a lift, and the connection is often the limiting pressure component. A hose size chart that stops at the bore misses the two things that decide whether the line is usable.<\/p>\n\n\n\n<p>That is why the guide is best read with three companions: a bend radius table, a weight figure and a fitting rating. Each answers a question that the bore alone cannot.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-you-use-the-chart-in-a-tender\">How Do You Use the Chart in a Tender?<\/h2>\n\n\n\n<p>Write the flow, the allowable drop, the product and the route. Then let the supplier propose a size and show the calculation.<\/p>\n\n\n\n<p>A tender that specifies only the bore invites a hose that fits the drawing and not the duty. One that specifies the flow invites a proposal that can be checked, which is the point of a size chart in the first place.<\/p>\n\n\n\n<p>Add the connection and the handling to the same line. A hose size chart entry that says 4 inch is incomplete until it says which fitting and how the hose is moved.<\/p>\n\n\n\n<p>Where two sizes are close, ask for both. The price difference is usually smaller than the cost of a line that loads too slowly for a decade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"where-does-the-chart-mislead\">Where Does the Chart Mislead?<\/h2>\n\n\n\n<p>Three ways.<\/p>\n\n\n\n<p>It suggests that bore is a free choice, when the pump and the connection often fix it. It implies that a larger bore is better, when weight and cost rise with it. And it hides the tolerance question, which decides whether the hose fits at all.<\/p>\n\n\n\n<p>Read the hose size chart as a starting point that narrows the options, then confirm with the four checks above. A pressure drop per meter value is worth carrying into that check, because it converts a size into a time. A hose size chart is a map, not a route, and the route is the calculation.<\/p>\n\n\n\n<p>Two habits make the calculation reliable. Keep the chart and the pump curve on the same page, because a bore that suits the flow may not suit the pump. And record the size chosen against the duty, so the next line is specified from data rather than from memory.<\/p>\n\n\n\n<p>A chart also has to be read at the right temperature. Viscosity falls as product warms, so a bore that is marginal on a cold morning may be generous by mid-afternoon. Where a line runs across a shift, size it on the coldest condition it will see and note the assumption on the drawing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-i-convert-hose-inches-to-millimeters\">How do I convert hose inches to millimeters?<\/h3>\n\n\n\n<p>Multiply by 25.4. A 2 inch hose is nominally 50 mm, a 3 inch is 80 mm and a 4 inch is 100 mm, with the exact figure depending on the standard.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"is-the-bore-the-same-as-the-outside-diameter\">Is the bore the same as the outside diameter?<\/h3>\n\n\n\n<p>No. Bore is the inside passage, which is what flow depends on. The outside diameter includes the wall and the cover.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-size-hose-do-i-need-for-20-cubic-meters-an-hour\">What size hose do I need for 20 cubic meters an hour?<\/h3>\n\n\n\n<p>It depends on the allowable drop and the viscosity. Use the flow band and the pressure drop calculation rather than a single figure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"does-a-bigger-bore-always-load-faster\">Does a bigger bore always load faster?<\/h3>\n\n\n\n<p>A bigger bore loads faster only up to the limit of the pump and the connection. Beyond that, the extra diameter adds weight and cost without reducing time.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-does-pressure-drop-matter-more-on-a-long-hose\">Why does pressure drop matter more on a long hose?<\/h3>\n\n\n\n<p>Drop accumulates with length and with each bend. A short line tolerates a small bore that a long route cannot.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-i-reduce-a-hose-size-with-a-reducer\">Can I reduce a hose size with a reducer?<\/h3>\n\n\n\n<p>Physically yes, and it defeats the purpose. A reducer adds a loss and makes the larger hose behave like the smaller one.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-the-most-common-sizing-mistake\">What is the most common sizing mistake?<\/h3>\n\n\n\n<p>Sizing on the connection or on the previous hose rather than on the flow and the drop. The second hose then repeats the first one&#8217;s problem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-i-size-a-replacement-when-the-old-marking-has-worn-off\">How do I size a replacement when the old marking has worn off?<\/h3>\n\n\n\n<p>Measure the bore at the end and the outside diameter over the cover, then note the fitting standard. Treat the old nominal size as a starting point only, because a worn marking is the usual reason a replacement arrives one size out.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"about-henghua\">About HENGHUA<\/h2>\n\n\n\n<p>HENGHUA supplies composite hose from 1 inch to 8 inch and will confirm the bore, bend radius and assembly rating for a duty rather than quoting a size from the connection alone. Measured bore values are available on request.<\/p>\n\n\n\n<p>Send the flow, the allowable drop and the route, and we will return the size that fits, with the bend radius the layout has to respect.<\/p>","protected":false},"excerpt":{"rendered":"<p>A hose size chart is a decision tool, not a conversion table. The bore decides flow, the flow decides loading time, and the loading time decides whether the size was right; the flow sizing guide turns that chain into a number. Inches and millimeters are only the first two columns. This guide gives the size [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7038,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_surecart_dashboard_logo_width":"180px","_surecart_dashboard_show_logo":true,"_surecart_dashboard_navigation_orders":true,"_surecart_dashboard_navigation_invoices":true,"_surecart_dashboard_navigation_subscriptions":true,"_surecart_dashboard_navigation_downloads":true,"_surecart_dashboard_navigation_saved":true,"_surecart_dashboard_navigation_billing":true,"_surecart_dashboard_navigation_account":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[2880,2881,550,2882],"class_list":["post-7055","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-composite-hose-size","tag-hose-bore-chart","tag-hose-size-chart","tag-pressure-drop-per-meter"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.5 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Composite Hose Size Chart: Bore, Flow and Drop | HENGHUA<\/title>\n<meta name=\"description\" content=\"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-size-chart\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop\" \/>\n<meta property=\"og:description\" content=\"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-size-chart\/\" \/>\n<meta property=\"og:site_name\" content=\"HENGHUA\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T08:21:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T08:21:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"goodheart786@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"goodheart786@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/\"},\"author\":{\"name\":\"goodheart786@gmail.com\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/person\\\/28fdea90953f1958bdc26b600560c5c7\"},\"headline\":\"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop\",\"datePublished\":\"2026-11-17T08:21:36+00:00\",\"dateModified\":\"2026-11-17T08:21:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/\"},\"wordCount\":2264,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-size-chart-hero.jpg\",\"keywords\":[\"composite hose size\",\"hose bore chart\",\"hose size chart\",\"pressure drop per meter\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/\",\"name\":\"Composite Hose Size Chart: Bore, Flow and Drop | HENGHUA\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-size-chart-hero.jpg\",\"datePublished\":\"2026-11-17T08:21:36+00:00\",\"dateModified\":\"2026-11-17T08:21:38+00:00\",\"description\":\"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-size-chart-hero.jpg\",\"contentUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-size-chart-hero.jpg\",\"width\":800,\"height\":600,\"caption\":\"Two composite hose ends of different bore side by side on a bench, cut faces toward the camera\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-size-chart\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.henghuahose.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#website\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/\",\"name\":\"HENGHUA\",\"description\":\"Powering Your Industry, Worldwide.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\"},\"alternateName\":\"HENGHUA Hose\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.henghuahose.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\",\"name\":\"HENGHUA\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/HENGHUA-Hose-Manufacturer-Logo.png\",\"contentUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/HENGHUA-Hose-Manufacturer-Logo.png\",\"width\":388,\"height\":90,\"caption\":\"HENGHUA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/person\\\/28fdea90953f1958bdc26b600560c5c7\",\"name\":\"goodheart786@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"caption\":\"goodheart786@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/henghuahose.com\"],\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/ko\\\/author\\\/goodheart786gmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Composite Hose Size Chart: Bore, Flow and Drop | HENGHUA","description":"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.henghuahose.com\/ko\/composite-hose-size-chart\/","og_locale":"ko_KR","og_type":"article","og_title":"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop","og_description":"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.","og_url":"https:\/\/www.henghuahose.com\/ko\/composite-hose-size-chart\/","og_site_name":"HENGHUA","article_published_time":"2026-11-17T08:21:36+00:00","article_modified_time":"2026-11-17T08:21:38+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg","type":"image\/jpeg"}],"author":"goodheart786@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"goodheart786@gmail.com","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"11\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#article","isPartOf":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/"},"author":{"name":"goodheart786@gmail.com","@id":"https:\/\/www.henghuahose.com\/#\/schema\/person\/28fdea90953f1958bdc26b600560c5c7"},"headline":"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop","datePublished":"2026-11-17T08:21:36+00:00","dateModified":"2026-11-17T08:21:38+00:00","mainEntityOfPage":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/"},"wordCount":2264,"commentCount":0,"publisher":{"@id":"https:\/\/www.henghuahose.com\/#organization"},"image":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#primaryimage"},"thumbnailUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg","keywords":["composite hose size","hose bore chart","hose size chart","pressure drop per meter"],"articleSection":["Blog"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/","url":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/","name":"Composite Hose Size Chart: Bore, Flow and Drop | HENGHUA","isPartOf":{"@id":"https:\/\/www.henghuahose.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#primaryimage"},"image":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#primaryimage"},"thumbnailUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg","datePublished":"2026-11-17T08:21:36+00:00","dateModified":"2026-11-17T08:21:38+00:00","description":"A hose size chart linking bore in inches and millimeters to flow, velocity and pressure drop, with the bend radius and weight that go with each size.","breadcrumb":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.henghuahose.com\/composite-hose-size-chart\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#primaryimage","url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg","contentUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-size-chart-hero.jpg","width":800,"height":600,"caption":"Two composite hose ends of different bore side by side on a bench, cut faces toward the camera"},{"@type":"BreadcrumbList","@id":"https:\/\/www.henghuahose.com\/composite-hose-size-chart\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.henghuahose.com\/"},{"@type":"ListItem","position":2,"name":"Composite Hose Size Chart: Bore, Flow Rate and Pressure Drop"}]},{"@type":"WebSite","@id":"https:\/\/www.henghuahose.com\/#website","url":"https:\/\/www.henghuahose.com\/","name":"\ud5dd\ud654","description":"\uc804 \uc138\uacc4 \uc0b0\uc5c5\uc5d0 \ud798\uc744 \uc2e4\uc5b4\ub4dc\ub9bd\ub2c8\ub2e4.","publisher":{"@id":"https:\/\/www.henghuahose.com\/#organization"},"alternateName":"HENGHUA Hose","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.henghuahose.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/www.henghuahose.com\/#organization","name":"\ud5dd\ud654","url":"https:\/\/www.henghuahose.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.henghuahose.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/05\/HENGHUA-Hose-Manufacturer-Logo.png","contentUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/05\/HENGHUA-Hose-Manufacturer-Logo.png","width":388,"height":90,"caption":"HENGHUA"},"image":{"@id":"https:\/\/www.henghuahose.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.henghuahose.com\/#\/schema\/person\/28fdea90953f1958bdc26b600560c5c7","name":"goodheart786@gmail.com","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","caption":"goodheart786@gmail.com"},"sameAs":["https:\/\/henghuahose.com"],"url":"https:\/\/www.henghuahose.com\/ko\/author\/goodheart786gmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/7055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/comments?post=7055"}],"version-history":[{"count":2,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/7055\/revisions"}],"predecessor-version":[{"id":7080,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/7055\/revisions\/7080"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/media\/7038"}],"wp:attachment":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/media?parent=7055"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/categories?post=7055"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/tags?post=7055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}