{"id":6944,"date":"2026-11-16T03:29:48","date_gmt":"2026-11-16T03:29:48","guid":{"rendered":"https:\/\/www.henghuahose.com\/?p=6944"},"modified":"2026-11-16T03:29:50","modified_gmt":"2026-11-16T03:29:50","slug":"composite-hose-standards-map","status":"publish","type":"post","link":"https:\/\/www.henghuahose.com\/ko\/composite-hose-standards-map\/","title":{"rendered":"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2"},"content":{"rendered":"<p>Composite hose standards divide by duty, not by product. EN 13765 governs thermoplastic multilayer hose for hydrocarbons, solvents and chemicals. BS 5842 is the withdrawn British specification that still appears in legacy tenders. USCG 33 CFR 154.500 sets marking and design rules for transfer hose at US terminals. EN 1474-2 covers LNG transfer, which EN 13765 explicitly excludes.<\/p>\n\n\n\n<p>This composite hose standards map shows which standard applies to which duty, what each one actually requires, and how to write a tender that names the right one.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg\" alt=\"Stack of standards documents beside a coiled composite hose on a bench\" class=\"wp-image-6932\" srcset=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg 800w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero-300x225.jpg 300w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero-768x576.jpg 768w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero-16x12.jpg 16w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>Figure 1. A stack of standards documents beside a coiled composite hose on a bench. The duty decides which one governs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"which-standard-governs-which-duty\">Which Standard Governs Which Duty?<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\uc758\ubb34<\/th><th>Governing document<\/th><th>What it fixes<\/th><\/tr><\/thead><tbody><tr><td>Chemical and hydrocarbon transfer, general industry<\/td><td>EN 13765:2018<\/td><td>Types, pressure, temperature, vacuum, marking<\/td><\/tr><tr><td>Legacy British tenders, dock and road tanker<\/td><td>BS 5842:1980<\/td><td>Older assembly requirements, withdrawn<\/td><\/tr><tr><td>US terminal oil and hazardous material transfer<\/td><td>USCG 33 CFR 154.500<\/td><td>Burst factor, MAWP, connections, marking<\/td><\/tr><tr><td>LNG transfer, ship to shore<\/td><td>EN 1474-2<\/td><td>Design and testing of transfer systems<\/td><\/tr><tr><td>Cryogenic industrial gas<\/td><td>EN 12434<\/td><td>Cryogenic hose performance and testing<\/td><\/tr><tr><td>Corrugated metal hose<\/td><td>ISO 10380<\/td><td>Metal hose design and testing<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Table 1. Composite hose standards by duty. Only the first row describes the hose itself; the others describe a system, a legacy text or a different construction.<\/em><\/p>\n\n\n\n<p>The first distinction to hold on to is scope. The terminal rule is the clearest example of a document that regulates equipment rather than a product, and it is where most arguments about composite hose standards start. The <a href=\"https:\/\/www.henghuahose.com\/ko\/en-13765-composite-hose-types\/\" target=\"_blank\" rel=\"noopener\">type guide<\/a> and the <a href=\"https:\/\/www.henghuahose.com\/ko\/uscg-33-cfr-154-500-composite-hose\/\" target=\"_blank\" rel=\"noopener\">154.500 clause reading<\/a> cover the two main rows. EN 13765 is a hose standard: it tells you what a hose of a given type must do. The USCG rule is a terminal regulation: it tells you what the equipment at a facility must be, including marking and test records.<\/p>\n\n\n\n<p>A hose can satisfy EN 13765 and still fail a 154.500 inspection, because the latter asks for a burst factor relative to the relief valve setting and for specific marking. Both are legitimate; they answer different questions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-does-en-13765-actually-require\">What Does EN 13765 Actually Require?<\/h2>\n\n\n\n<p>Four types, distinguished by pressure and temperature, plus requirements for construction, marking and testing. The type table is the part most buyers know, and it is the part most often misquoted.<\/p>\n\n\n\n<p>The standard also fixes the wire materials, the cover, the bore range from 25 mm to 300 mm, and the test regime behind each type. Its exclusions matter as much as its content, and the en 13765 vs bs 5842 question is usually really a scope question: it does not cover aircraft fuelling, retail fuel dispensing, oil burners, LPG or LNG, fire fighting or refrigeration circuits.<\/p>\n\n\n\n<p>That exclusion list is why an LNG project cannot be specified to EN 13765 even though the product looks similar. The right reference there is the LNG standard, with EN 12434 for cryogenic industrial gas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"is-bs-5842-still-usable\">Is BS 5842 Still Usable?<\/h2>\n\n\n\n<p>BS 5842:1980 is the British specification for thermoplastic hose assemblies for dock, road and tanker use. It was confirmed in 1986 and has since been withdrawn, and the European specification now covers the same field.<\/p>\n\n\n\n<p>It still appears in older terminal manuals and in tenders copied from them. When it does, the practical answer is to quote the current standard and attach the values the old reference implied: type, pressure, temperature and test values.<\/p>\n\n\n\n<p>The comparison is covered in detail elsewhere on this site, including why a class or type designation from the older text does not map one to one onto the current table.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-does-uscg-33-cfr-154-500-require\">What Does USCG 33 CFR 154.500 Require?<\/h2>\n\n\n\n<p>The clause governs hose assemblies used for oil or hazardous material transfer at a facility. It sets a burst factor measured against the relief valve setting plus static head, a maximum allowable working pressure above that setting, connection standards, and marking rules.<\/p>\n\n\n\n<p>Three marking points are worth memorising. The hose must be marked for oil service or hazardous material service, with the maximum allowable working pressure and the date of manufacture. The burst pressure and test pressure must not be marked on the hose; they belong in the records.<\/p>\n\n\n\n<p>Testing sits in a companion clause, which requires each assembly to be pressure tested to a factor above its working pressure, at least annually, with the record kept. The hose marking and the record together are what an inspector checks.<\/p>\n\n\n\n<p>Note what the clause does not do: it does not set electrical resistance limits. Where continuity is required, it comes from the facility&#8217;s operating documents rather than from 154.500 itself.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"where-does-the-lng-standard-fit\">Where Does the LNG standard Fit?<\/h2>\n\n\n\n<p>The LNG transfer standard covers design and testing of systems, including the hose strings used in ship-to-shore transfer. It is a system standard, not a product catalogue, and it assumes a temperature regime far below anything in EN 13765.<\/p>\n\n\n\n<p>For a composite hose standards question on an LNG project, the answer is that the hose sits inside a system approved to that standard, and the hose maker&#8217;s data feeds that approval. A hose certificate alone does not satisfy the system requirement, and the <a href=\"https:\/\/www.henghuahose.com\/ko\/chemical-transfer-hose-inspection-program\/\" target=\"_blank\" rel=\"noopener\">inspection guide<\/a> is the closer reference for terminal work.<\/p>\n\n\n\n<p>Cryogenic industrial gas follows a different route again, through EN 12434, which covers performance and testing for cryogenic hose.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-do-you-write-the-tender\">How Do You Write the Tender?<\/h2>\n\n\n\n<p>Name one governing document per line item, then the values you need. A tender that names two standards for one hose invites an offer that satisfies neither.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>State the duty: chemical, hydrocarbon, LNG or terminal transfer.<\/li>\n\n\n\n<li>Name the document: EN 13765:2018, 33 CFR 154.500, or EN 1474-2.<\/li>\n\n\n\n<li>Give type, bore, pressure at temperature and vacuum if needed.<\/li>\n\n\n\n<li>Require marking that matches the document.<\/li>\n\n\n\n<li>Require the test record and the certificate scope.<\/li>\n\n\n\n<li>State the exclusion: what the hose will not be used for.<\/li>\n<\/ul>\n\n\n\n<p>The last line prevents the most common failure. A supplier who knows the hose will never see food or LNG will not overspecify, and a buyer who states it cannot later claim the hose was wrong.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid.jpg\" alt=\"A composite hose coil on a pallet in a warehouse aisle\" class=\"wp-image-6933\" srcset=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid.jpg 800w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid-300x225.jpg 300w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid-768x576.jpg 768w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid-16x12.jpg 16w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-grid-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>Figure 2. One coil on a pallet in a store aisle. The duty decides which document governs this build.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-about-national-and-class-rules\">What About National and Class Rules?<\/h2>\n\n\n\n<p>Flag states, classification societies and national regulators add requirements on top of the standards above. A vessel transfer may need a class society&#8217;s approval of the hose assembly, and a terminal may need a local permit that references its own code.<\/p>\n\n\n\n<p>Those requirements sit above the product standard and are usually documented by the operator rather than the hose maker. The hose maker&#8217;s job is to supply the type test, the marking and the traceability that the approval relies on.<\/p>\n\n\n\n<p>For composite hose standards work, the practical rule is to ask early which approvals the project needs, because a certificate that arrives after the hose is installed rarely helps.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"where-do-national-rules-diverge\">Where Do National Rules Diverge?<\/h2>\n\n\n\n<p>The international standard and the national regulation answer different questions, and the gap between them is where projects lose time.<\/p>\n\n\n\n<p>EN 13765 fixes the values a type must withstand. A national rule says what equipment may be used at a facility and how it must be marked and tested. A hose can meet the first and still fail an inspection under the second, which is the most common problem in practice. The reverse is also true: an assembly built to a terminal rule may not carry the type test a product buyer expects. Both failures cost a project the same fortnight.<\/p>\n\n\n\n<p>The practical reading of en 13765 vs bs 5842, like the uscg hose standard question, follows the same logic, and the <a href=\"https:\/\/www.henghuahose.com\/ko\/bs-5842-vs-en-13765\/\" target=\"_blank\" rel=\"noopener\">BS 5842 comparison<\/a> covers it in full. The older British text described assemblies for dock, road and tanker duty; the current European text describes hose types. Neither is a terminal regulation, and neither replaces one, which is why a terminal rule never settles a European tender.<\/p>\n\n\n\n<p>Where a project spans markets, list the documents per market rather than one global set. A hose that satisfies a European tender may need additional marking for a US terminal, and that marking has to be designed in rather than added later.<\/p>\n\n\n\n<p>Three project states change the map. A new build writes the register before the tender. A retrofit starts from the document the existing hose was bought under. An audit starts from the marking on the hose and works back to the document, which is the reverse of the order the table is written in.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-does-a-certificate-fit-the-map\">How Does a Certificate Fit the Map?<\/h2>\n\n\n\n<p>A certificate sits beside the standard, not on top of it. It records that a design was tested to a named edition, for named types and bores.<\/p>\n\n\n\n<p>A uscg hose standard question is answered by the regulation&#8217;s marking and test clauses, not by a certificate. The regulation asks for marking and test records, and the certificate supports the design rather than the installation.<\/p>\n\n\n\n<p>That distinction matters in a tender response. Offering a certificate where a regulation applies looks thorough and answers the wrong question.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-should-a-standards-register-contain\">What Should a Standards Register Contain?<\/h2>\n\n\n\n<p>Four rows, four documents, one page. A register is one page that a project team keeps, and it prevents the same argument twice. It also gives a new engineer the answer without a meeting, which is the real test of whether a file is usable.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Duty and location for each hose application<\/li>\n\n\n\n<li>Governing document, with edition and year<\/li>\n\n\n\n<li>Type, bore and pressure required<\/li>\n\n\n\n<li>Marking required by that document<\/li>\n\n\n\n<li>Test and record requirements<\/li>\n\n\n\n<li>Certificate scope, if any<\/li>\n\n\n\n<li>The document that governs where two apply<\/li>\n\n\n\n<li>The review date, so a stale row is visible rather than assumed<\/li>\n<\/ul>\n\n\n\n<p>Rows are short on purpose. A longer table gets skimmed, and a skimmed table is not a control. The last line resolves the common conflict. When a national rule and a product standard both apply, name which one governs the marking and which governs the performance.<\/p>\n\n\n\n<p>Two tie-breaks cover almost every conflict. Where a product standard and a facility rule both apply, the product standard governs the hose&#8217;s pressure and temperature values, and the facility rule governs the marking and the test interval.<\/p>\n\n\n\n<p>Where two editions of one document both appear, the edition named in the order governs, and the older edition is referenced only to explain a legacy tender.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register.jpg\" alt=\"An open ring binder with blank lined pages beside a coiled composite hose and a pen\" class=\"wp-image-6934\" srcset=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register.jpg 800w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register-300x225.jpg 300w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register-768x576.jpg 768w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register-16x12.jpg 16w, https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-register-600x450.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>Figure 3. An open binder beside a coiled hose. The register is only useful when it is reviewed against the hose on site.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-changes-for-lng\">What Changes for LNG?<\/h2>\n\n\n\n<p>A terminal question, like an LNG question, is about a system rather than a product. The LNG transfer standard covers a system rather than a hose, and it assumes a temperature regime outside EN 13765. A composite hose standards answer for LNG therefore starts with the system approval, not with the hose type.<\/p>\n\n\n\n<p>Cryogenic industrial gas follows its own route, and metal hose follows another. A terminal query and an aviation query sit outside this map entirely. A map that shows four documents as four rows is more useful than one that implies a single product standard covers all low-temperature duty.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Document<\/th><th>Marking required<\/th><th>Record required<\/th><\/tr><\/thead><tbody><tr><td>EN 13765<\/td><td>Type, bore, maker, batch<\/td><td>Type test values<\/td><\/tr><tr><td>BS 5842<\/td><td>Legacy assembly marking<\/td><td>Assembly test record<\/td><\/tr><tr><td>USCG 154.500<\/td><td>Service, MAWP, date of manufacture<\/td><td>Annual pressure test<\/td><\/tr><tr><td>LNG standard<\/td><td>System-specific<\/td><td>System approval file<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Table 2. What each document asks you to put on the hose, and what it asks you to keep. The two lists are rarely the same.<\/em><\/p>\n\n\n\n<p>A uscg hose standard reference and an en 13765 vs bs 5842 reference are both answered by naming the edition and the clause. The map is a starting point for a project file, and every row should be checked against the edition in force when the order is placed.<\/p>\n\n\n\n<p>Keeping the file current is the part most teams skip. An edition change, a new terminal rule or a class requirement can invalidate a row that was correct last year, and the review takes an hour when it is done at the start of a project rather than during an inspection. Put the review date beside each row, and the register stays useful for years. A file nobody reviews is a file nobody trusts, and an untrusted file gets rebuilt from scratch on the next project.<\/p>\n\n\n\n<p>A stale row is worse than a missing one, because it looks answered. When an edition changes, retire the row rather than overwrite it, and keep the old value beside the date it stopped applying. That way an audit can see what the hose was bought against.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"which-standard-applies-to-a-chemical-composite-hose\">Which standard applies to a chemical composite hose?<\/h3>\n\n\n\n<p>EN 13765:2018 for general chemical and hydrocarbon transfer. Terminal transfer in US waters adds 33 CFR 154.500 requirements on marking and testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"does-en-13765-cover-lng\">Does EN 13765 cover LNG?<\/h3>\n\n\n\n<p>No. It excludes LPG and LNG, and the LNG transfer route is EN 1474-2, with EN 12434 for cryogenic industrial gas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"can-i-still-specify-bs-5842\">Can I still specify BS 5842?<\/h3>\n\n\n\n<p>You can reference it, but there is little point. Cite the current standard and list the values that the older text implied.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"is-33-cfr-154-500-a-product-standard\">Is 33 CFR 154.500 a product standard?<\/h3>\n\n\n\n<p>No. It is a facility regulation that sets requirements for hose assemblies used at terminals, including marking and test records.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"do-i-need-both-en-13765-and-uscg-compliance\">Do I need both EN 13765 and USCG compliance?<\/h3>\n\n\n\n<p>For a US terminal handling oil or hazardous material, the hose is usually built to EN 13765 and the assembly meets 154.500 marking and test rules. They are complementary.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-about-metal-hose-on-an-lng-line\">What about metal hose on an LNG line?<\/h3>\n\n\n\n<p>Corrugated metal hose follows ISO 10380 for design and testing, and it appears in LNG service where its temperature capability is needed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-i-know-which-document-a-supplier-built-to\">How do I know which document a supplier built to?<\/h3>\n\n\n\n<p>From the marking and the test record. A datasheet should name the standard and the edition, and the marking should carry the type.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"about-henghua\">About HENGHUA<\/h2>\n\n\n\n<p>HENGHUA builds composite hose to EN 13765 and supplies the marking and test records that terminal regulations rely on. We do not claim LNG or cryogenic capability beyond what our product pages state, and we will say when a project needs a different construction.<\/p>\n\n\n\n<p>Send the duty and the governing document, and we will confirm which build applies and what documentation will accompany it.<\/p>","protected":false},"excerpt":{"rendered":"<p>Composite hose standards divide by duty, not by product. EN 13765 governs thermoplastic multilayer hose for hydrocarbons, solvents and chemicals. BS 5842 is the withdrawn British specification that still appears in legacy tenders. USCG 33 CFR 154.500 sets marking and design rules for transfer hose at US terminals. EN 1474-2 covers LNG transfer, which EN [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":6932,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_surecart_dashboard_logo_width":"180px","_surecart_dashboard_show_logo":true,"_surecart_dashboard_navigation_orders":true,"_surecart_dashboard_navigation_invoices":true,"_surecart_dashboard_navigation_subscriptions":true,"_surecart_dashboard_navigation_downloads":true,"_surecart_dashboard_navigation_saved":true,"_surecart_dashboard_navigation_billing":true,"_surecart_dashboard_navigation_account":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[2828,2829,2831,2830],"class_list":["post-6944","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-composite-hose-standards","tag-en-13765-vs-bs-5842","tag-en-1474-2","tag-uscg-hose-standard"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.5 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Composite Hose Standards Map: EN 13765 to USCG | HENGHUA<\/title>\n<meta name=\"description\" content=\"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-standards-map\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2\" \/>\n<meta property=\"og:description\" content=\"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.henghuahose.com\/ko\/composite-hose-standards-map\/\" \/>\n<meta property=\"og:site_name\" content=\"HENGHUA\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T03:29:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-16T03:29:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"goodheart786@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"goodheart786@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/\"},\"author\":{\"name\":\"goodheart786@gmail.com\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/person\\\/28fdea90953f1958bdc26b600560c5c7\"},\"headline\":\"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2\",\"datePublished\":\"2026-11-16T03:29:48+00:00\",\"dateModified\":\"2026-11-16T03:29:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/\"},\"wordCount\":2318,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-standards-map-hero.jpg\",\"keywords\":[\"composite hose standards\",\"en 13765 vs bs 5842\",\"en 1474-2\",\"uscg hose standard\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/\",\"name\":\"Composite Hose Standards Map: EN 13765 to USCG | HENGHUA\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-standards-map-hero.jpg\",\"datePublished\":\"2026-11-16T03:29:48+00:00\",\"dateModified\":\"2026-11-16T03:29:50+00:00\",\"description\":\"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-standards-map-hero.jpg\",\"contentUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/composite-hose-standards-map-hero.jpg\",\"width\":800,\"height\":600,\"caption\":\"Stack of standards documents beside a coiled composite hose on a bench\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/composite-hose-standards-map\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.henghuahose.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#website\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/\",\"name\":\"HENGHUA\",\"description\":\"Powering Your Industry, Worldwide.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\"},\"alternateName\":\"HENGHUA Hose\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.henghuahose.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#organization\",\"name\":\"HENGHUA\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/HENGHUA-Hose-Manufacturer-Logo.png\",\"contentUrl\":\"https:\\\/\\\/www.henghuahose.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/HENGHUA-Hose-Manufacturer-Logo.png\",\"width\":388,\"height\":90,\"caption\":\"HENGHUA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.henghuahose.com\\\/#\\\/schema\\\/person\\\/28fdea90953f1958bdc26b600560c5c7\",\"name\":\"goodheart786@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g\",\"caption\":\"goodheart786@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/henghuahose.com\"],\"url\":\"https:\\\/\\\/www.henghuahose.com\\\/ko\\\/author\\\/goodheart786gmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Composite Hose Standards Map: EN 13765 to USCG | HENGHUA","description":"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.henghuahose.com\/ko\/composite-hose-standards-map\/","og_locale":"ko_KR","og_type":"article","og_title":"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2","og_description":"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.","og_url":"https:\/\/www.henghuahose.com\/ko\/composite-hose-standards-map\/","og_site_name":"HENGHUA","article_published_time":"2026-11-16T03:29:48+00:00","article_modified_time":"2026-11-16T03:29:50+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg","type":"image\/jpeg"}],"author":"goodheart786@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"goodheart786@gmail.com","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"12\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#article","isPartOf":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/"},"author":{"name":"goodheart786@gmail.com","@id":"https:\/\/www.henghuahose.com\/#\/schema\/person\/28fdea90953f1958bdc26b600560c5c7"},"headline":"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2","datePublished":"2026-11-16T03:29:48+00:00","dateModified":"2026-11-16T03:29:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/"},"wordCount":2318,"commentCount":0,"publisher":{"@id":"https:\/\/www.henghuahose.com\/#organization"},"image":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#primaryimage"},"thumbnailUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg","keywords":["composite hose standards","en 13765 vs bs 5842","en 1474-2","uscg hose standard"],"articleSection":["Blog"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/","url":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/","name":"Composite Hose Standards Map: EN 13765 to USCG | HENGHUA","isPartOf":{"@id":"https:\/\/www.henghuahose.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#primaryimage"},"image":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#primaryimage"},"thumbnailUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg","datePublished":"2026-11-16T03:29:48+00:00","dateModified":"2026-11-16T03:29:50+00:00","description":"Which standard governs which composite hose duty: EN 13765 scope, BS 5842 status, USCG 33 CFR 154.500 marking and the LNG transfer standard, in one map.","breadcrumb":{"@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.henghuahose.com\/composite-hose-standards-map\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#primaryimage","url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg","contentUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/11\/composite-hose-standards-map-hero.jpg","width":800,"height":600,"caption":"Stack of standards documents beside a coiled composite hose on a bench"},{"@type":"BreadcrumbList","@id":"https:\/\/www.henghuahose.com\/composite-hose-standards-map\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.henghuahose.com\/"},{"@type":"ListItem","position":2,"name":"Composite Hose Standards Map: EN 13765, BS 5842, USCG and EN 1474-2"}]},{"@type":"WebSite","@id":"https:\/\/www.henghuahose.com\/#website","url":"https:\/\/www.henghuahose.com\/","name":"\ud5dd\ud654","description":"\uc804 \uc138\uacc4 \uc0b0\uc5c5\uc5d0 \ud798\uc744 \uc2e4\uc5b4\ub4dc\ub9bd\ub2c8\ub2e4.","publisher":{"@id":"https:\/\/www.henghuahose.com\/#organization"},"alternateName":"HENGHUA Hose","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.henghuahose.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/www.henghuahose.com\/#organization","name":"\ud5dd\ud654","url":"https:\/\/www.henghuahose.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.henghuahose.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/05\/HENGHUA-Hose-Manufacturer-Logo.png","contentUrl":"https:\/\/www.henghuahose.com\/wp-content\/uploads\/2026\/05\/HENGHUA-Hose-Manufacturer-Logo.png","width":388,"height":90,"caption":"HENGHUA"},"image":{"@id":"https:\/\/www.henghuahose.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.henghuahose.com\/#\/schema\/person\/28fdea90953f1958bdc26b600560c5c7","name":"goodheart786@gmail.com","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e1786ba73a3780e524c9584c9578a9c8d9baa7e82407695918f6b784c79979bf?s=96&d=mm&r=g","caption":"goodheart786@gmail.com"},"sameAs":["https:\/\/henghuahose.com"],"url":"https:\/\/www.henghuahose.com\/ko\/author\/goodheart786gmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/6944","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/comments?post=6944"}],"version-history":[{"count":1,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/6944\/revisions"}],"predecessor-version":[{"id":6945,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/posts\/6944\/revisions\/6945"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/media\/6932"}],"wp:attachment":[{"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/media?parent=6944"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/categories?post=6944"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.henghuahose.com\/ko\/wp-json\/wp\/v2\/tags?post=6944"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}