SAE Split Flange Clamps 6000 PSI Code 62: FS Series

Why These SAE Split Flange Clamps Pass the Compliance Gate
These SAE split flange clamps, series FS, are the four-bolt clamp halves that lock a Code 62 flange head against a flat port pad. The profile follows the Code 62 envelope printed on the data sheet, ISO 6162 – SAE J518, at the nominal 6000 psi family level with the pressure rating printed per clamp. For an OEM, FS clamps hold high-pressure flange type hose fittings on pumps and valves where 3000 psi hardware is not enough. For a distributor, one line covers six flange sizes from 1/2″ to 2″. For a maintenance team, they are the direct replacement when a Code 62 clamp is worn, corroded, or lost.
- Code 62 split flange clamp halves dimensioned per ISO 6162 – SAE J518, as printed on the FS data sheet.
- Six flange sizes from 1/2″ to 2″, each rated 42 MPa (6000 psi class) in the table.
- Bolt hole diameter (D), bolt spacing (C and E), and the recommended BOLT size printed for every clamp.
- High-strength carbon steel, heat treated, with plating options matched to the environment.
- Mates with HENGHUA SAE flange type hose fittings that carry the same Code 62 flange size.
주요 강점
- Code 62 envelope compliance. FS clamps follow the SAE J518 / ISO 6162-2 geometry, so these code 62 flange clamps pair with any Code 62 flange head of the matching flange size, including the HENGHUA code 62 flange hose fitting range.
- One series, six flange sizes. From 1/2″ to 2″, the matrix covers high-pressure pumps, valves, and hydrostatic drive lines with a single supplier line.
- Printed bolt and pressure data. Every row lists the BOLT size to order and the 42 MPa rating, so the purchasing check is done on the page.
- Corrosion protection matched to duty. Trivalent zinc (96 h salt spray), zinc-nickel (720 h), or Dacromet (1000 h); 304/316L stainless on request.
기술 사양
What Are SAE Split Flange Clamps?
A flange connection has three parts: the flange head on the hose fitting, the O-ring between the head and the port pad, and the split flange clamps that hold everything together. Each pair of SAE split flange clamps consists of two clamp halves and four bolts; the halves close over the flange head and the bolts pull the head face down onto the pad. The result is a compact, vibration-resistant joint that holds high-pressure impulses without loosening.
This FS page covers the clamp halves only. The flange head arrives on the hose fitting itself, so when you buy flange type hydraulic hose fittings you still need the matching split flange clamp halves, the O-ring, and the bolts to complete the joint. Code 62 is the 6000 psi family (ISO 6162-2); Code 61 is the 3000 psi family (ISO 6162-1). The head, the clamp, and the pad must all be the same code and the same flange size.
차원 데이터
Dimension symbols follow the drawing printed on the data sheet. All values are in millimeters (mm).
| 기호 | 설명 |
|---|---|
| A | Overall horizontal width of the assembled clamp halves. |
| B | Overall vertical height of the assembled clamp pair. |
| C | Horizontal distance between bolt-hole centers across the split line. |
| D | Diameter of the bolt holes. |
| E | Vertical center-to-center distance between the two bolt holes of one clamp half. |
| BOLT | Recommended bolt size to order for that clamp, as printed on the data sheet. |
| MPa | Pressure rating of the clamp, as printed on the data sheet. |
전체 치수 표 (부품 번호 매트릭스)
The matrix below is transcribed directly from the FS data sheet. In each part number, FS is the Code 62 split flange clamp series and the two digits are the flange dash in 1/16″ increments, for example FS-32 means a 2″ flange (dash 32). Dimensions are in mm as printed; BOLT and MPa values are copied exactly from the sheet.
| 부품 번호. | 플랜지 크기 | A | B | C | D | E | BOLT | MPa |
|---|---|---|---|---|---|---|---|---|
| FS-08 | 1/2인치 | 56.3 | 49.2 | 40.5 | 9 | 18.2 | M8X30 | 42 |
| FS-12 | 3/4인치 | 71.4 | 61.8 | 50.8 | 11 | 23.8 | M10X35 | 42 |
| FS-16 | 1″ | 81 | 71.4 | 57.2 | 13 | 27.8 | M12X45 | 42 |
| FS-20 | 1.1/4″ | 95.3 | 79.2 | 66.7 | 15 | 31.8 | M14X50 | 42 |
| FS-24 | 1.1/2″ | 112.8 | 96.8 | 79.4 | 17 | 36.6 | M16X55 | 42 |
| FS-32 | 2″ | 133.4 | 115.6 | 96.8 | 21 | 44.4 | M20X70 | 42 |
Footnote as printed on the data sheet: Bolt should be ordered separately. The SAE split flange clamps are supplied without bolts, so add the BOLT column size to your order and confirm the length and property class against the port pad.
재료 및 열처리
| 항목 | 사양 |
|---|---|
| 재료 | High-strength carbon steel, cold-forged or hot-forged, grades 20#/35#/45#; 304/316L stainless steel available on request. |
| 열처리 | Carburized and quenched; core hardness HRC 20-28 with batch hardness records. |
| 표면 | Trivalent zinc plating (96 h salt spray), zinc-nickel (720 h), or Dacromet (1000 h); stainless parts can run untreated. |
작동 압력 및 작동 범위
| 매개변수 | 값 |
|---|---|
| Flange class | Code 62, nominal 6000 psi family per ISO 6162 – SAE J518. |
| Pressure rating | 42 MPa as printed for every FS clamp on the data sheet, matching the 6000 psi Code 62 class. |
| Joint working pressure | Limited by the flange head fitting, the O-ring, and the bolts; use the lowest of the component ratings. |
| 공장 시험 | 100% dimensional inspection of machined clamps; finished flange assemblies are 100% pressure tested. |
| 온도 범위 | Typically -40°C to +120°C; system derating depends on the hose and seal materials. |
For these code 62 flange clamps, treat the printed 42 MPa value as the rating of the clamp pair alone. The complete joint never exceeds the weakest component, so verify the flange fitting rating and the bolt property class against the data sheet that ships with every order.
선정 및 주문
부품 번호 매트릭스 읽는 방법
Read the series first: FS means code 62 flange clamps for the 6000 psi family, per ISO 6162 – SAE J518. Then read the digits as the flange dash in 1/16″ increments: FS-08 is 1/2″, FS-12 is 3/4″, FS-16 is 1″, FS-20 is 1.1/4″, FS-24 is 1.1/2″, and FS-32 is 2″. Match that flange size to the flange head on your hose fitting and to the port pad on the machine; all three must agree.
플랜지 규격 및 대시 규격 표
| 플랜지 크기 | 플랜지 대시 | CLAMP PART NO. |
|---|---|---|
| 1/2인치 | 08 | FS-08 |
| 3/4인치 | 12 | FS-12 |
| 1″ | 16 | FS-16 |
| 1.1/4″ | 20 | FS-20 |
| 1.1/2″ | 24 | FS-24 |
| 2″ | 32 | FS-32 |
If the machine runs 3000 psi Code 61 connections, the FS series does not fit; order the FL series split flange clamps instead and keep the code separate in your stock.
교차 참조 서비스
Send us your legacy part number, a drawing, or a physical sample, and we map it to the closest HENGHUA FS code. If you currently run Code 62 split flange clamp halves sourced under legacy numbers, include the old part number and a photo of the clamp so the match can be confirmed before you order. The service is free for volume buyers, and the confirmation includes flange size, dash, dimensions, and the BOLT size so your team can verify before ordering.
포장 및 물류
| 항목 | 상세 정보 |
|---|---|
| 내부 포장 | 10 pairs per box, with labels. |
| Shipping pack | Bulk cartons on request; batch number on every carton. |
| 출처 | Made in China, HENGHUA factory. |
| 문서 | Mill test reports (MTR) and certificates available with the order. |
| 샘플 | Sample support with worldwide shipping; 24 h quotation response. |
조립 및 사용 안내서
Four-Step Flange Assembly Method
- Confirm the flange specification. Check that the clamp series is FS (Code 62), and that the flange size and dash match the flange head on the hose fitting and the port pad.
- Fit the O-ring. Seat the O-ring in the groove on the flange head face, keep it clean, and apply a light lubricant.
- Close the split flange clamp halves over the flange head. Align the bolt holes with the threaded holes in the port pad and keep both halves square to the pad face.
- Insert the specified bolts and tighten them in a diagonal sequence in two or three passes. Use the bolt size from the BOLT column and the torque from the data sheet that ships with the order.
Matching the Flange Connection
The SAE split flange clamps work with any SAE flange type hose fitting that carries a Code 62 flange head of the same flange size. Center the head over the port, seat the O-ring, and follow the four steps above for every size in the FS range, from the 1/2″ clamp to the 2″ clamp. Never reuse a crushed O-ring or a clamp that has been deformed in service.
설치 시 주의사항
- Do not mix Code 62 (FS) and Code 61 (FL) hardware; the heads, clamps, bolt spacing, and pad dimensions are not interchangeable.
- Do not force an FS clamp onto a flange head of a different flange size, and never drill or ream the bolt holes to make it fit.
- Do not reuse clamp halves with cracks, heavy corrosion, or stretched bolt holes; a deformed clamp cannot hold the seal load.
- Bolts must be ordered separately. Using the wrong bolt size, length, or property class risks joint failure; confirm against the BOLT column and the port pad.
- Do not torque one bolt fully before the others. Tighten in a diagonal sequence in stages so the clamp loads evenly.
- Inspect the O-ring and the pad face before assembly; replace the O-ring if it is pinched, cut, or hardened.
- Use the torque value from the data sheet provided with every order. Do not rely on guesswork for high-pressure flange joints.
OEM 맞춤 제작 및 품질 추적성
사용자 지정 옵션
Surface finish can be set to zinc, zinc-nickel, or Dacromet; 304/316L material is available for corrosive duty; laser marking adds your logo and batch number to each clamp half. Custom packaging, private-label boxes, and mixed-size kits are standard OEM options with a 24 h quotation response.
품질 및 추적성 시스템
Incoming material, cold forming, machining, heat treatment, surface finishing, 100% inspection, marking, and packaging are each recorded for the SAE split flange clamps. A batch number traces back to the steel heat and the heat-treatment and inspection records. MTRs ship with the order, and BV/SGS third-party inspection can be arranged before shipment.
자주 묻는 질문
Q: What are SAE split flange clamps used for? A: Two clamp halves and four bolts lock a Code 62 flange head against a flat port pad, sealing the O-ring between the head and the pad. They complete the flange connection started by a flange type hose fitting.
Q: Is the FS series Code 61 or Code 62? A: Code 62. The FS series is the SAE split flange clamps family for 6000 psi nominal connections per ISO 6162 – SAE J518. For 3000 psi Code 61 systems, use the FL series; the two codes never mix.
Q: Are the bolts included with the clamps? A: No. The bolts must be ordered separately, as stated on the data sheet. Use the BOLT column in the matrix, for example M20X70 for FS-32, and confirm length and property class against the port pad.
Q: Which hose fittings do these clamps fit? A: Any flange type hose fitting with a Code 62 flange head of the same flange size, such as the HENGHUA SAE code 62 flange hose fittings. Match the clamp flange size to the head and the pad.
Q: How do I read a part number like FS-20? A: FS is the Code 62 split flange clamp series and 20 is the flange dash in 1/16″ increments, which is a 1.1/4″ flange. Check the FLANGE SIZE column in the matrix for the full list.
Q: What does the MPa figure mean in the table? A: It is the pressure rating printed for each FS clamp on the data sheet, 42 MPa for every size in the 6000 psi Code 62 class. The finished joint is limited by the weakest of the head, O-ring, and bolts.
Q: What materials and finishes are available? A: High-strength carbon steel with carburized case hardening, HRC 20-28, is standard. Trivalent zinc, zinc-nickel, or Dacromet plating is selected by environment, and 304/316L stainless is available on request.
Q: Can HENGHUA make custom-marked clamps for an OEM program? A: Yes. Laser marking, custom finish, stainless material, and private-label packaging are standard options, with batch traceability and a 24 h quotation response.
견적 요청하기
Tell us the flange size and series (FS, Code 62), the quantity of clamp pairs, the surface finish, and whether bolts are needed, and we will confirm price and lead time within 24 hours. OEM buyers can add legacy part numbers or drawings for cross reference. Samples ship worldwide so your team can gauge these SAE split flange clamps before you commit.
전체 내용 보기 플랜지 피팅 온 가족을 위한 제품 라인, 또는 문의하기 견적, 제강 시험 보고서 및 샘플을 요청하시려면.
당사 제품에 대한 문의
당사는 유압 피팅 및 장비의 글로벌 공급업체로서, 다양한 산업 분야에 원스톱 조달 솔루션을 제공하고 있습니다. 당사의 제품에는 다음이 포함됩니다. 유압 호스, 피팅, 어댑터, 퀵 커플러, 커넥터, 호스 가드, 유압 장비 그 밖에도 운영이 원활하고 효율적으로 이루어지도록 하는 데 필요한 모든 것을 제공합니다.
아래 양식을 통해 귀사의 요구 사항을 알려주십시오. 저희 팀이 전문적인 조언과 맞춤형 견적을 제공하여 귀사의 업무가 원활하게 진행될 수 있도록 도와드리겠습니다.
- 유압 호스2323개 상품
- 강선 나선형 유압 호스66개 상품
- 강선 편조 유압 호스1010개 상품
- 섬유 보강 유압 호스33개 상품
- 열가소성 유압 호스33개 상품
- 산업용 호스7575개 상품
- 공기 호스99개 상품
- 물 호스1111개 상품
- 오일 호스1616개 상품
- 화학용 호스66개 상품
- 복합 호스1616개 상품
- 화학 복합 호스33개 상품
- 해양용 복합 호스55개 상품
- 석유용 복합 호스55개 상품
- 고온용 복합재 호스11개 상품
- PTFE 복합 호스11개 상품
- 극저온용 복합재 호스11개 상품
- 스팀 호스33개 상품
- 다목적 호스22개 상품
- 식품 및 음료용 호스44개 상품
- 콘크리트 호스44개 상품
- 시멘트 호스22개 상품
- 자재 운반용 호스1111개 상품
- 준설 호스44개 상품
- 유압 피팅166166개 상품
- 재사용 가능한 호스 연결부66개 상품
- 소켓이 없는 호스 피팅88개 상품
- JIC 유압 피팅1616개 상품
- 미터법 유압 피팅4141개 상품
- NPT 유압 피팅66개 상품
- BSP 유압 피팅2626개 상품
- SAE 유압 피팅3030개 상품
- 밴조 유압 피팅44개 상품
- ORFS 유압 피팅1111개 상품
- 페룰1111개 상품
- 플랜지 피팅2626개 상품
- 원피스 피팅2424개 상품
- 유압 어댑터149149개 상품
- Industrial Hose Couplings4747개 상품
- Camlock Couplings1010개 상품
- Camlock Gaskets and Handles22개 상품
- Composite Hose Fittings33개 상품
- European Couplings55개 상품
- Ferrules and Hose Tails33개 상품
- Fire Hose Couplings77개 상품
- Hose Clamps and Whipchecks33개 상품
- Quick Couplings44개 상품
- Tank, Bulk and Specialty Fittings1010개 상품
- Hose Crimping Machines1111개 상품